| Categories | LoRaWAN |
|---|---|
| Brand Name: | ZONEWU |
| Model Number: | LW101B-DO |
| Certification: | CE/RoHS |
| Place of Origin: | Xiamen |
| MOQ: | 1 |
| Price: | Contact Us |
| Payment Terms: | T/T |
| Supply Ability: | 500 |
| Delivery Time: | 21 days |
| Packaging Details: | 37x26x5 cm |
| Product Name: | LoRaWAN Integral DO Transmitter |
| Power Supply: | ER26500 Li-SOCl2 8500 mAh battery,3.6V |
| DC12/24V: | 200g |
| Operating Temperature: | 0~40℃ |
| Measuring Principle: | Fluorescence |
| Measuring Range: | 0~20mg/L (0~200% saturation) |
| Measurement Error: | ±3%FS;±0.5℃(25℃ |
| Resolution Ratio: | 0.01mg/L;0.1%;0.1℃ |
| Frequency: | CN470/IN865/EU868/RU864/US915/AU915/ KR920/AS923-1&2&3&4 |
| Mode: | OTAA Class A |
| Communication Protocol: | LoRaWAN 1.0.3 |
LoRaWAN dissolved oxygen sensor is a wireless dissolved oxygen sensor that uses fluorescence measurement principle. It is designed for scenarios such as outdoor, factory, aquaculture, etc. where power supply is inconvenient or scattered at multiple locations. Built in ER26500 lithium-ion battery (8500 mAh, 3.6V), combined with LoRa low-power communication technology, can achieve maintenance free operation for more than a year, truly solving the problems of difficult wiring and power supply in traditional wired monitoring.
1, Fluorescence method measurement, no oxygen consumption or
calibration required
Using advanced optical fluorescence technology, the sensor measures
the fluorescence quenching effect to invert the dissolved oxygen
concentration, without consuming oxygen, and is not affected by
flow rate and electromagnetic interference, making the measurement
more stable. Supports a wide range of 0-20mg/L (0-200% saturation),
with a resolution of up to 0.01mg/L and an accuracy of ± 3% FS.
Coupled with high-precision temperature compensation of ± 0.5 ℃, it
ensures the authenticity and reliability of the data.
2, Available in both freshwater and seawater versions, suitable for
different water bodies
Provide two models, LDO (freshwater version) and LDOS (seawater
version), optimized for freshwater environments (such as rivers,
lakes, and tap water) and high salinity seawater environments (such
as marine aquaculture and nearshore monitoring), respectively, to
meet the precise monitoring needs of multiple scenarios.
3, Long life fluorescent film, easier to maintain
The lifespan of fluorescent film can reach one year under normal
usage conditions, significantly reducing replacement frequency and
backend maintenance costs. The sensor comes standard with a 5-meter
cable by default (length can be customized), supporting a pressure
resistance of 0.6Mpa, suitable for deep water or pipeline
installation environments.
4, LoRaWAN wireless transmission, compatible with global frequency
bands
Supports global mainstream LoRaWAN frequency bands such as
CN470/IN865/EU868/US915/AU915/KR920/AS923, out of the box, can
quickly connect to standard LoRa gateways and cloud platforms, and
achieve remote real-time viewing of dissolved oxygen change trends,
historical data playback, and threshold alarms.
5, Extremely low power consumption design, battery powered
long-lasting durability
Excellent overall power consumption control, relying on LoRaWAN
Class C mode and configurable reporting cycle (default 10 minutes),
a single battery can support long-term field deployment without the
need for external solar or mains power, making it particularly
suitable for the construction of distributed water quality
monitoring networks.
| Power Supply | ER26500 Li-SOCl2 8500 mAh battery,3.6V |
| LW301B Weight | 200g |
| Operating Temperature | 0~40℃ |
| Measuring Principle | Fluorescence |
| Measuring Range | 0~20mg/L (0~200% saturation) |
| Measurement Error | ±3%FS;±0.5℃(25℃ |
| Resolution Ratio | 0.01mg/L;0.1%;0.1℃ |
| Fluorescent Film Lifespan | Normal use for 1 year |
| LDO | Fluorescence dissolved oxygen transmitter (freshwater version) |
| LDOS | Fluorescence dissolved oxygen transmitter (seawater version) |
| Pressurization | 0.6Mpa |
DO Transmitter Line length | Default 5m (other lengths can be customized) |
| Frequency | CN470/IN865/EU868/RU864/US915/AU915/ KR920/AS923-1&2&3&4 |
| Mode | OTAA Class A |
| Reporting cycle | 60min(Default reporting cycle) |
| Battery Life | ≤2 years (Depending on the reporting cycle) Note: Due to the high power consumption of DO sensor, it is not recommended to use short cycle data reporting. |
| Communication Protocol | LoRaWAN,LoRa TDMA Networking |
Equipment information (Reference) | AppEUI:0000000000000001 DevEUI:aaaa202404150001 AppKey:00001111222233334444555566667777 MAC Version: LoRaWAN 1.0.3 |
Single gross weight: 1.200 KG
Single package size: 37X26X5 cm





1.Are you manufacture?
A:Yes,we are Tranmitter manufacturer and exporter in China with more than 10 years of CE,ROHS,FCC,ISO and 11 patents experience.
2.Do you offer OEM services?
A:Yes,we can provide you with OEM services and design housings and logos.
3.DO you offer free samples?
A:Sorry,we don't offer free samples.After ordering in bulk,we will deduct the sample fee from the second order.
|
Buy cheap Digital LoRaWAN K+ Ion Water Quality Sensor LW114D , Cloud-Based Monitoring , OTAA Class A Communication product
Buy cheap ZONEWU LoRaWAN Industrial-Grade ORP Online Monitor for Sewage/Drinking Water/Swimming Pools product
Buy cheap LW104D Online LoRaWAN Residual Chlorine Sensor | 0-10mg/L Water Quality Monitoring product