| Categories | DC UPS Power Supply |
|---|---|
| Brand Name: | TBB |
| Model Number: | iDU500-48 |
| Certification: | CE |
| Place of Origin: | China |
| MOQ: | 1piece |
| Price: | Negotiable |
| Payment Terms: | T/T |
| Delivery Time: | 5-30 days based on order qty |
| Packaging Details: | Carton box |
| Output Voltage: | 12VDC |
| Peak Power: | 500W |
| Communication: | RS485 protocol |
| Efficiency: | 90% |
| Protection: | Output short circuit |
| Multiple charge: | Five stage |
| Working temperature: | -40℃-70℃. |
iDU is a DC UPS integrating multiple functions into one unit, including a smart battery charger, battery monitor and the load management. The built-in professional adaptive charging algorithm with automatic temperature charging makes it suitable for composing a power backup system for various outdoor equipments, such as DAS, RF and FTU etc.
Features:
Charging Curve

From the picture, you will see the charging curve, and help you understand more about our DC UPS charging. ( status for Soft Start~Bulk~Absorption~Float~Recycle)
Specification
| Model | iDU500-12 | iDU500-24 | iDU500-48 | |
| Output voltage (V) | 14.4 | 28.8 | 57.6 | |
| Output current(A) | Nominal current | 8 | 3.5 | 2 |
| Peak current(15S) | 20 | 20 | 10 | |
| Nominal Input Voltage | 165-265VAC,50/60HZ | |||
| Charging curve | 3 steps smart charging | |||
| Temperature compensation | Automatic temperature compensation | |||
| Absorption voltage(V) | 14.4 | 28.8 | 57.6 | |
| Floating voltage(V) | 13.5 | 27 | 54 | |
| Charging current (A) | 3 | 1.5 | 1 | |
| Equilization | Automatic/Manual | |||
| Efficiency | 90% | |||
| Ripple noise | ≤500mVp-p | |||
| Voltage precision | ≤2% | |||
| Cooling | no fans | |||
| Working temperature | -40℃~ +70℃: full load at 60℃ and derating 60% at 70℃ | |||
| Communication | RS485 | |||
| Dry contact | AC grid fault, Battery low voltage, unit fault and Battery equilization | |||
| Battery low voltage protection(VDC) | 11 | 22 | 44 | |
| Battery EQ voltage protection(VDC) | 11.5 | 23 | 46 | |
| Protection | ||||
| Output short circuit | Unit cut down the outputs,restart automatically when the issue disappears | |||
| Battery connection reverse polarity | No output | |||
| Charger over temperature | Derate the output | |||
| Battery over temperature | Stop charging | |||
| Certification | ||||
| LVD | EN60335-1,EN60335-2-29 | |||
| EMC | EN55014-1,EN55014-2,EN61000-3-2,EN61000-3-3 | |||
| Structure | ||||
| Outcase | Aluminum | |||
| Dimension | 168x110x45 | 168x110x45 | 168x110x45 | |
| 168x110x45 | 1kgs | 1kgs | 1kgs | |
| IP protection | IP55 | |||
| Mounting | Wall mount | |||
| Isulation safety | ||||
| Isulation resistance | ≥50M | |||
| Dimension | 2.5KV/1min/5mA | |||
|