...endure input current ranging from 50A to 100A. If the monitored circuit malfunctions, it can output zero phase current which is 500 times smaller than the input current with the suggested 500 turns ratio so that the power supply is cut off to protect the
...endure input current ranging from 50A to 100A. If the monitored circuit malfunctions, it can output zero phase current which is 500 times smaller than the input current with the suggested 500 turns ratio so that the power supply is cut off to protect the more
Brand Name:GFUVE
Model Number:LZCG530-10-100
Place of Origin:China
-
...current is destroyed, there is zero sequence current; The two is that when the normal non charged metal casing appears on the ground voltage (normal, the metal shell and the earth are zero potential). The zero sequence current transformer is the leakage protection device through the zero sequence current transformer...
-
...Zero-Sequence Casting Resin High Voltage Current Transformer Zero sequence Transformer The basic principle of zero-sequence current protection is based on Kirchhoff's current law: the algebraic sum of the complex current flowing into any node of the circuit equals zero. The vector sum of each phase current is equal to zero under the normal condition of circuit and electrical equipment. Therefore, the secondary winding of zero sequence current
...Zero-Sequence Casting Resin High Voltage Current Transformer Zero sequence Transformer The basic principle of zero-sequence current protection is based on Kirchhoff's current law: the algebraic sum of the complex current flowing into any node of the circuit equals zero. The vector sum of each phase current is equal to zero under the normal condition of circuit and electrical equipment. Therefore, the secondary winding of zero sequence current more
Brand Name:QIUPU
Model Number:LJZ-
Place of Origin:WENZHOU
High Tension Zero Sequence Current Transformer Casting Resin Material High Voltage
-
... in which two magnetic materials of different permeability are provided so as to eliminate a range where the leakage current interrupter is inoperable without lowering its ability to distinguish noise components. The different magnetic materials may be
... in which two magnetic materials of different permeability are provided so as to eliminate a range where the leakage current interrupter is inoperable without lowering its ability to distinguish noise components. The different magnetic materials may be more
Brand Name:KRIPAL
Model Number:KCT40
Place of Origin:China
ZCT40 Zero Sequence Current Transformer 40mm for Earth Leakage Relay
-
100A 50/60Hz Sensor Split Core Current Transformer DC/AC Current Transformer Introduction: CY-FLXK-XX Flexible Steel Strips Zero-Sequence Current Transformer is specially designed for assembling and disconnecting the existing main busbar or cable ...
-
... magneitc field interference • Measure the current directly • It is with the diode to save people's life • Meet the ROHS requirement • High accuracy at 10-130% of rated current • AC isolation resistance: 3KV for 60s • Swing open for ease of
-
LXK-80 1 PC $33.00 . Yueqing Renhe Electrical Technology Co.,Ltd is a high-teach enterprise professionalize in research and development production ,sales and service of intelligent products.Main products include intelligent digital meter,multi -function ...
LXK-80 1 PC $33.00 . Yueqing Renhe Electrical Technology Co.,Ltd is a high-teach enterprise professionalize in research and development production ,sales and service of intelligent products.Main products include intelligent digital meter,multi -function ... more
Brand Name:SUCHEN
Model Number:LXK-80
Place of Origin:Zhejiang, China
LXK-80 Zero Sequence Current Transformer
-
... grounding systems, fire leakage systems, three-phase current unbalance detection and other equipment. Main Feature Enclosed by epoxy resin, good seismic performance Perforation method, the hole diameter is from φ...
... grounding systems, fire leakage systems, three-phase current unbalance detection and other equipment. Main Feature Enclosed by epoxy resin, good seismic performance Perforation method, the hole diameter is from φ... more
Brand Name:Shinhom
Model Number:HKC Series
Place of Origin:China
IEC60076 Zero Sequence Current Sense Transformer Active Type
-
...zero-sequence current measurement and data transmit function, it indicates fault when earth fault happened in cable, It can help line finder find the fault quickly .shorten power-off time,improve the reliability of power supply,be convenient for users to monitor the zero-sequence load current...
...zero-sequence current measurement and data transmit function, it indicates fault when earth fault happened in cable, It can help line finder find the fault quickly .shorten power-off time,improve the reliability of power supply,be convenient for users to monitor the zero-sequence load current... more
Brand Name:Tianyihongda
Model Number:TYHD-1
Place of Origin:Beijing,China
Zero Sequence Current Measurement Fiber Optic Fault Locator 9600 Bps Data Rate
-
...Zero Phase Current Transformer (ZCT) Model: ZCT2605 Magnetic Core: Nanocrystalline Core Outer Diameter: 30mm Height: 10mm Finished: Epoxy encapsulated. Performance: 18mA output 5.4mV +/- 1mV at Load 200 OHM (Cumstom made is available) Nanocrystalline current...
...Zero Phase Current Transformer (ZCT) Model: ZCT2605 Magnetic Core: Nanocrystalline Core Outer Diameter: 30mm Height: 10mm Finished: Epoxy encapsulated. Performance: 18mA output 5.4mV +/- 1mV at Load 200 OHM (Cumstom made is available) Nanocrystalline current... more
Brand Name:King Magnetics
Model Number:ZCT2605
Place of Origin:China
Zero Phase current transformer (ZCT)
-
General APM series power meters of ACREL are power meters that are designed according to IEC standards and synchronized with international advanced technology. APM series meters have full power measurement, energy statistics, analysis of power quality and ...
-
...Zero Sequence Low Voltage CT Current Transformer Detail parameters These are ring type CT & suitable for the measurement of the sum of three phase currents in a 3-ph cable. Under normal operating conditions this sum is zero. In the event of an earth-fawt the sum of the current is equal to the zero sequence current...
...Zero Sequence Low Voltage CT Current Transformer Detail parameters These are ring type CT & suitable for the measurement of the sum of three phase currents in a 3-ph cable. Under normal operating conditions this sum is zero. In the event of an earth-fawt the sum of the current is equal to the zero sequence current... more
Brand Name:YOMIN
Model Number:LMZ
Place of Origin:Zhejiang, China
High Precision Zero Sequence Low Voltage CT Current Transformer
-
...Current Transformer Manufacturer Power coil are suitable for the application in weak magnetic field, can be used for manufacturing high sensitivity and small power transformer, low power magnetic amplifier, relay, head of magnetic recording device, zero sequence current transformer, power converter, precision current transformer, magnetic amplifier, power transformer, choke, pulse transformer...
...Current Transformer Manufacturer Power coil are suitable for the application in weak magnetic field, can be used for manufacturing high sensitivity and small power transformer, low power magnetic amplifier, relay, head of magnetic recording device, zero sequence current transformer, power converter, precision current transformer, magnetic amplifier, power transformer, choke, pulse transformer... more
Brand Name:HEMEI
Model Number:54.5*75.5*20.5mm
Place of Origin:China
32MW Split Core Current Transformer
-
... Used for:low voltage CT(and zero-sequence instrument transformers) electronic components such as: ignition, regulator, electronic transformers, network transformers, pump motor, ignition coil, transformer, negative ion generator, AC capacitor, (vertical,
... Used for:low voltage CT(and zero-sequence instrument transformers) electronic components such as: ignition, regulator, electronic transformers, network transformers, pump motor, ignition coil, transformer, negative ion generator, AC capacitor, (vertical, more
Brand Name:JT-RESIN
Model Number:8219
Place of Origin:China
Heat Resistance Clear Casting Resin For Zero - Sequence Transformer
-
...zero sequence transformer (10/√3)KV/(6.5/3)V Introduction The 10KV zero-sequence transformer adopts the principle of capacitive voltage division and uses temperature-stable ceramic dielectric GC as raw material. It is mainly suitable for 12KV on-column switches, ring network cabinets and other scenarios. Electrical parameters Zero sequence voltage rated transformation...
...zero sequence transformer (10/√3)KV/(6.5/3)V Introduction The 10KV zero-sequence transformer adopts the principle of capacitive voltage division and uses temperature-stable ceramic dielectric GC as raw material. It is mainly suitable for 12KV on-column switches, ring network cabinets and other scenarios. Electrical parameters Zero sequence voltage rated transformation... more
Brand Name:XIWUER
Model Number:EVY3.2/4.2/5NF
Place of Origin:XIAN,CHINA
OEM Cylindrical Capacitive Voltage Detector 3P Zero Sequence Transformer
-
...stability Small change for output voltage after passing the heavy current IDC A variety of configuration and output characteristics Three Phase Precision Current Transformer-CT01 Series Shenzhen Dowis Electronics Co., Ltd. is a professional manufacturer of
...stability Small change for output voltage after passing the heavy current IDC A variety of configuration and output characteristics Three Phase Precision Current Transformer-CT01 Series Shenzhen Dowis Electronics Co., Ltd. is a professional manufacturer of more
Brand Name:Dowis
Model Number:CT01 series
Place of Origin:CN
50Hz To 400Hz Three Phase Precision Current Transformer CT01 Series
-
Zero Single Phase BH - 60 Current Sense Transformer , Electrical Current Transformer Current transformer features 1.Material: ABS flame retardant enclosure, earth leakage protective cap,large iron core, pure red copper. 2. Three colors for protective cap...
-
Low Voltage RCT 0.66kv and Below Zero Phase CT Wth PCB Mount Used For kWh Meter Description : The RCT current transformers are used in 0.66kv and below electricity system for protection and measuring purposes. The RCTs conforms the standards IEC60044-1 & ...
Low Voltage RCT 0.66kv and Below Zero Phase CT Wth PCB Mount Used For kWh Meter Description : The RCT current transformers are used in 0.66kv and below electricity system for protection and measuring purposes. The RCTs conforms the standards IEC60044-1 & ... more
Brand Name:YOMIN
Model Number:RCT series
Place of Origin:Zhejiang , China ( Mainland )
KWh Meter Low Voltage LV Current Transformers Wth PCB Mount
-
... transformer and also used to transformer voltage or current in the circuit. However, transforming voltage and current by power transformer aims at transferring electric energy while transforming voltage and current by transformer aims at measuring and