-
... Meet the requirements for DC Immunity Insulation withstand voltage:3750V Range of working Frequency:50Hz~400Hz ·Ambient temperature:-40°C~85°C Application: Suitable for single-phase electricity meter as well as ...
... Meet the requirements for DC Immunity Insulation withstand voltage:3750V Range of working Frequency:50Hz~400Hz ·Ambient temperature:-40°C~85°C Application: Suitable for single-phase electricity meter as well as ... more
Brand Name:CTWELL
Model Number:Miniature Current Transformer
Place of Origin:China
-
... phase to three phase. With wide current range, it is perfect for the test of I-P close link meter. Features: High accuracy through active electronic error compensation. Direct perforated installation Wide current dynamic range: 10mA --120A (Primary side)
... phase to three phase. With wide current range, it is perfect for the test of I-P close link meter. Features: High accuracy through active electronic error compensation. Direct perforated installation Wide current dynamic range: 10mA --120A (Primary side) more
Brand Name:KRE
Model Number:KE632x
Place of Origin:China
120A Isolation Current Transformer For I - P Close Link Meter Testing
-
120A Low Voltage Ct 0.2 Current Transformer Current Transducer 1.Main Features: ● DC Immunity with Better Phase Error ● Tooled Casing Instead of Traditional Tape ● Irregular Central Hole for Easy Assembly ● Various Busbar Integration to Adapt Application 2.Technical Parameters: Main Parameter Current Ratio 5(120)A/2mA Coil Turns 2500 Burden 10Ω Dielectric Strength More than AC4000V Accuracy 0.1 class Rated Frequency 50~60Hz Current...
120A Low Voltage Ct 0.2 Current Transformer Current Transducer 1.Main Features: ● DC Immunity with Better Phase Error ● Tooled Casing Instead of Traditional Tape ● Irregular Central Hole for Easy Assembly ● Various Busbar Integration to Adapt Application 2.Technical Parameters: Main Parameter Current Ratio 5(120)A/2mA Coil Turns 2500 Burden 10Ω Dielectric Strength More than AC4000V Accuracy 0.1 class Rated Frequency 50~60Hz Current... more
Brand Name:IVY
Model Number:IVY-CT-CS-05-120ADC-MA01
Place of Origin:Zhejiang
120A Low Voltage Ct 0.2 Current Transformer Current Transducer
-
...current transformer : Model No 1 :GWCTSA010 Ratio : 3000:1 Rated input: 5A 10A 20A 50A 75A Accuracy class: 1.0s 3.0s Rated primary current:120A Protection: 5 times protection ,10 times protection like 25A 50A 100A 200A 250A 385A 500A 750A Model No.2 :GWCTSA016 Ratio :3000:1 Rated input: 75A 100A 150A Accuracy class: 0.5 1.0S Rated accuracy limit primary current...
...current transformer : Model No 1 :GWCTSA010 Ratio : 3000:1 Rated input: 5A 10A 20A 50A 75A Accuracy class: 1.0s 3.0s Rated primary current:120A Protection: 5 times protection ,10 times protection like 25A 50A 100A 200A 250A 385A 500A 750A Model No.2 :GWCTSA016 Ratio :3000:1 Rated input: 75A 100A 150A Accuracy class: 0.5 1.0S Rated accuracy limit primary current... more
Brand Name:grewin
Place of Origin:Tianjin, China
Certification:CE ROHS
75A 100A 150A output 0.333v 5A split core current transformer current sensor for meter and energy system
-
...Current Transformer ACST3110F can be mounted to existing panels, such as control centers or load centers, to measure or monitor wattage. These CTs can be mounted without removing existing cables for easier installation Specifications: Winding (Turn) : 3000 Ts Max. Current : 120A Rated current: 50A Output Current...
...Current Transformer ACST3110F can be mounted to existing panels, such as control centers or load centers, to measure or monitor wattage. These CTs can be mounted without removing existing cables for easier installation Specifications: Winding (Turn) : 3000 Ts Max. Current : 120A Rated current: 50A Output Current... more
Brand Name:Shinhom
Model Number:ACST3110F
Place of Origin:China
Black Split Core Current Transformer Easy Installation For Control / Load Center
-
Basic parameter: Rated input current:0.01~120A Features: fully compatible with similar foreign products Use: for the current measurement, monitoring and protection of AC motor, lighting equipment, air compressor and so on. Lead length:TwentyCM The ...
-
... Current Transformers 05. U Series Current Transformers 06. Multi Phase Current Transformers 07. Current Transformers Set 08. Anti Magnetic Series Current Transformers 09. Power CT 10. Current Transformer Groupware 11. HPT Series Potential Transformers 12.
... Current Transformers 05. U Series Current Transformers 06. Multi Phase Current Transformers 07. Current Transformers Set 08. Anti Magnetic Series Current Transformers 09. Power CT 10. Current Transformer Groupware 11. HPT Series Potential Transformers 12. more
Brand Name:Shenzhen Chuangyin Co.,Ltd.
Model Number:CYSDJ-15/630
Place of Origin:China
Anti Magnetic Current Transformer For Energy Meter CT DC Immunity Function
-
...250V Output Current: AC 0-120A HES-1Bx Transformer Tester Measure item: Ratio errors & Phase errors of the CT and PT Rated current: 5A, 1A Rated voltage: 100V, 110V, 115V, 120V, 150V, 200V, 220V, 230V Multiplier: 1/√3, 1/3, 1, 1.5, 2 Accuracy class: ±2%
...250V Output Current: AC 0-120A HES-1Bx Transformer Tester Measure item: Ratio errors & Phase errors of the CT and PT Rated current: 5A, 1A Rated voltage: 100V, 110V, 115V, 120V, 150V, 200V, 220V, 230V Multiplier: 1/√3, 1/3, 1, 1.5, 2 Accuracy class: ±2% more
Brand Name:HNMC
Model Number:HES-30
Place of Origin:China
0.01S Class CT PT Test Equipment , 220KV Current Transformer Test Set
-
...current transformer , class 0.5 class1.0 current transformer Specifications: CT Current Transformer: 1. Voltage: 0.5KV 2. Frequency:50Hz 3. Primary current: 5-1200A 4. Secondary current: 5A Production Description: 1. Specifications of CT Current Transformer CT Current Transformer is designed for current...
...current transformer , class 0.5 class1.0 current transformer Specifications: CT Current Transformer: 1. Voltage: 0.5KV 2. Frequency:50Hz 3. Primary current: 5-1200A 4. Secondary current: 5A Production Description: 1. Specifications of CT Current Transformer CT Current Transformer is designed for current... more
Brand Name:YOMIN
Model Number:LMZ1-0.5
Place of Origin:ZHEJIAGN, CHINA
LMZ1-0.5 Ring Type Bus Bar Cast Resin LV Current Transformers Class 0.5 Class1.0
-
... transformer and also used to transformer voltage or current in the circuit. However, transforming voltage and current by power transformer aims at transferring electric energy while transforming voltage and current by transformer aims at measuring and
-
...Current Transformer Lamination Transformer 1.Product Description The EI19 Low Frequency Current Transformer is a compact and efficient transformer designed for low-frequency current measurement and monitoring applications. Featuring an EI19 laminated iron core, it offers high magnetic permeability and low core loss, ensuring accurate and reliable current...
...Current Transformer Lamination Transformer 1.Product Description The EI19 Low Frequency Current Transformer is a compact and efficient transformer designed for low-frequency current measurement and monitoring applications. Featuring an EI19 laminated iron core, it offers high magnetic permeability and low core loss, ensuring accurate and reliable current... more
Brand Name:ZXY
Model Number:ZXY-EI19
Place of Origin:China,shenzhen city.
EI19 1000:2 2000:2 Low Frequency Current Transformer Lamination Transformer
-
...6kA Mainly using for: Clamp-on current transformer Clip on current transformer Current transformer clamp Current transformer Technial index notes Testing current: 100mA to 6, 000A Accuracy class is divided into 0.1, 0.2, 0.5 and 1.0 grade Primary current:
-
...Current Transformer Micro AC Current Sensor for PV Inverter CT102 Current Transformer – Through-Hole Micro Current Sensor for Energy Meters & Power Monitoring The CT102 current transformer is a compact through-hole (donut/toroidal) micro current sensor engineered for accurate AC current...
...Current Transformer Micro AC Current Sensor for PV Inverter CT102 Current Transformer – Through-Hole Micro Current Sensor for Energy Meters & Power Monitoring The CT102 current transformer is a compact through-hole (donut/toroidal) micro current sensor engineered for accurate AC current... more
Brand Name:Chipsen
Model Number:CT102
Place of Origin:China
High Accuracy CT102 Current Transformer Micro AC Current Sensor For PV Inverter
-
... 2, Mainly using for: 1). Clamp-on Current Transformer, 2). Clip on current transformer, 3). Current transformer clamp, 4). Current transformer 3, Technial index notes 1), Testing current: 100mA to 6, 000A 2), Accuracy class is divided into 0.1, 0.2, 0.5
... 2, Mainly using for: 1). Clamp-on Current Transformer, 2). Clip on current transformer, 3). Current transformer clamp, 4). Current transformer 3, Technial index notes 1), Testing current: 100mA to 6, 000A 2), Accuracy class is divided into 0.1, 0.2, 0.5 more
Brand Name:HEMEI
Model Number:HM-CTC1535
Place of Origin:China
1000A 0.05 Class Clamp On Current Transformer Ct AC Monitoring
-
... a current in its secondary which is proportional to the current in its primary. Current transformers, along with voltage or potential transformers, are instrument transformers. Instrument transformers scale the large values of voltage or current to
-
... and they can help to measure the current or protect the equipment. Type Rated current ratio Accuracy class Circle diameter (mm) 0.5 class 1 class K-Φ24 (150-200)A/5(1)A 1 1 Φ24 (250-300)A/5(1)A 1.5 1 K-Φ36 (...
-
...Current Transformer-CT03 Series The miniature current transformer has no resistance at one time, and the ordinary micro current transformer is a transformer with a parallel resistor on two side, and the output is current. The miniature current transducer in the miniature current transformer is a parallel resistor on two side, and the output is voltage. Micro-current transformers...
...Current Transformer-CT03 Series The miniature current transformer has no resistance at one time, and the ordinary micro current transformer is a transformer with a parallel resistor on two side, and the output is current. The miniature current transducer in the miniature current transformer is a parallel resistor on two side, and the output is voltage. Micro-current transformers... more
Brand Name:Dowis
Model Number:CT03 series
Place of Origin:CN
4000VAC High Precision Mini Current Transformer CT03 Series
-
...Current Transformer for GIS The LZZBJ Post-type Current Transformer for GIS is a fully enclosed, epoxy resin cast-insulated pillar-type current transformer. Engineered for high performance in AC power systems (50Hz or 60Hz) with rated voltages up to 10kV, 20kV, and 35kV. Core Advantages & Applications Versatile Utility: Ideal for current...
...Current Transformer for GIS The LZZBJ Post-type Current Transformer for GIS is a fully enclosed, epoxy resin cast-insulated pillar-type current transformer. Engineered for high performance in AC power systems (50Hz or 60Hz) with rated voltages up to 10kV, 20kV, and 35kV. Core Advantages & Applications Versatile Utility: Ideal for current... more
Brand Name:EUE Power
Place of Origin:China
Rated Primary Current (A):5-3150
Fully Enclosed Post Type Current Transformer For GIS 10kV 20kV And 35kV
-
... connected with the Panel Meter or Relay and they can help to measure the current or protect the equipments. Low voltage current transformers are manufactured as of two types for measuring CT. Measuring CT: Measuring current transformers are constructed to
... connected with the Panel Meter or Relay and they can help to measure the current or protect the equipments. Low voltage current transformers are manufactured as of two types for measuring CT. Measuring CT: Measuring current transformers are constructed to more
Brand Name:YOMIN
Model Number:YMLZ-0.5S
Place of Origin:Zhejiang, China
400/5A 600/5A 800/5A resin material type class 0.5 Current Transformer