Brand Name: Forsentek
Model Number: FSSM
Certification: CE
Place of Origin: China
MOQ: 1pc
Payment Terms: T/T,Western Union or Paypal
Supply Ability: 3150pcs/month
Delivery Time: 3~25 working days
Packaging Details: Carton
Usage: Force measurement
Type: Miniature force sensor
Output: Analog Transducer
Capacity: 10N 20N 50N 100N 200N 300N 500N 1KN
Force direction: Tension/compression
Structure: Mini S-beam load cell
Threaded hole: M3/M4
  • Product Details
  • Company Profile

Micro force transducer 200lb 100lb 50lb 20lb tension measurement sensor

Micro force transducer 200lb 100lb 50lb 20lb tension measurement sensor

Micro force transducer FSSM offers a compact design for a variety of applications. the S Beam Load Cell series provides accuracy, compact design features, and a wide capacity range from 10N to 1000N to choose from.The mini load cell FSSM utilizes metal foil strain gauge technology to deliver 2.0mV/V output with maximum 0.1% non-linearity of the full scale,the compact design enables the FSSM to be easily embedded into machinery or test equipment – ideal for packaging machinery, assembly machinery or end-of-line test equipment.The sensor features threaded holes on two sides for the mounting of attachments or implements,this micro force sensor can be used for both tension and compression force measurement in applications with limited mounting space.You may find junior S beam load cell FSSM interchangeable with FUTEK load cell LSB200,Mark Miniature Force Sensors Series R04,flintec s-beam force sensor ISA,flintec load cell ISB,etc..In addition to the standard specifications,model FSSM can also be modified or customized to better fit clients' applications.

tension_measurement_sensor_20lb_50lb_100lb_200lb

Dimensions(in milimeter)

micro_Force_transducer_200lb_100lb_50lb_20lb

Ordering code

Part No.Force measuring rangeForce measurement direction
FSSM-10N0-10N / 0-1kgfTension/compression
FSSM-20N0-20N / 0-2kgf
FSSM-50N0-50N / 0-5kgf
FSSM-100N0-100N / 0-10kgf
FSSM-200N0-200N / 0-20kgf
FSSM-300N0-300N / 0-30kgf
FSSM-500N0-500N / 0-50kgf
FSSM-1kN0-1000N / 0-100kgf

Specifications

Capacity10N / 1kg / 2.2 lbf
20N / 2kg / 4.4 lbf
50N / 5kg / 10 lbf
100N / 10kg / 20 lbf
200N / 20kg / 45 lbf
300N / 30kg / 65 lbf
500N / 50kg / 110 lbf
1kN / 100kg / 220 lbf
Rated output2.0mV/V
Excitation3-12V
Zero balance±0.05mV/V
Nonlinearity±0.1% R.O.
Hysteresis±0.1% R.O.
Nonrepeatability±0.05% R.O.
Creep(5min)±0.1% R.O.
Safe overload150% F.S.
Ultimate overload200% F.S.
Compensated temperature-10...+40oC
Operating temperature-20...+60oC
Temperature shift zero±0.03% R.O./oC
Temperature shift span±0.02% R.O./oC
Input resistance380±30 ohms
Output resistance350±5 ohms
Insulation resistance>2000M ohms
Ingress protectionIP62
Material of elementStainless steel
CableØ2*4000mm 4-core shielded
Wiring code

Compression@
Red--Excitation+ Black--Excitation-

Green--Signal+ White--Signal-


Load Cell:A device which produces an output signal proportional to the applied weight or force.

Excitation: The voltage applied to the input terminals of the load cell.

Rated Capacity: The maximum axial load the load cell is designed to measure within its specifications.

Non-linearity: The maximum deviation of the calibration curve from a straight line drawn between the no-load and rated outputs; expressed as a percentage of the rated output and measured on increasing load only.

Non-repeatability: The maximum difference between load cell output readings for repeated loadings under identical loading and environmental conditions.

Hysteresis: The maximum difference between load cell output readings for the same applied load; one reading obtained by increasing the load from zero and the other by decreasing the load from rated output; usually measured at half rated output and expressed in percent of rated output.

Creep: The change in load cell output occurring with specified period of time, while under load, and with all environmental conditions and other variables remaining constant; usually measured with rated load applied.

Safe Overload: The maximum load in percent of rated capacity which can be applied without producing a permanent shift in performance characteristics beyond those specified.

Ultimate Overload: The maximum load in percent of rated capacity which can be applied without producing a structural failure.

Operating Temperature: The extremes of temperature within which a load cell will operate without permanent adverse change to any of its performance characteristics.

Temperature Shift Span: The change in output due to a change in load cell temperature; usually expressed as a percentage of load per degree Celsius change in temperature.

Temperature Shift Zero: The change in zero balance due to a change in ambient temperature; usually expressed in percent of rated output per degree Celsius change in temperature.

Input Resistance: The resistance of the load cell bridge circuit measured at the positive and negative excitation terminals with no load applied and with the output terminals open-circuited.

Output Resistance: The resistance of the transducer bridge circuit measured at the positive and negative signal terminals with no load applied and with the input terminals open-circuited.

Micro force transducer 200lb 100lb 50lb 20lb tension measurement sensor

micro_tension_transducer_20lb_50lb_100lb_200lb

Click here to download datasheet

Quality Micro force transducer 200lb 100lb 50lb 20lb tension measurement sensor for sale
Send your message to this supplier
 
*From:
*To: Forsentek Co., Limited
*Subject:
*Message:
Characters Remaining: (0/3000)
 
You may also be interested in :
Inquiry Cart 0
Company Info
  • Haven't found right suppliers
  • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
  • And this service is free of charge.
  • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
  • Submit Buying Request
    Contact Us Quickly